Procedure Steps
Step
1
2
3
4
5
Job aids
The following illustration shows a screen with three columns:
Configurable, In Use, and Last BootP. Use the Configurable column to
configure a new value for the field. The In Use column shows the current
value used by the switch and the Last BootP column displays a value
assigned to the field by a BootP request. These fields are shown in the
following illustration.
Figure 18
Sample Web-based Management Interface screen
The following table describes the fields in the previous illustration.
Table 16
IP Configuration fields
Field
BootP Request
Mode
Copyright © 2008–2009 Nortel Networks
Action
Connect a computer to the switch through a data port using a
standard RJ-45 network cable.
Open a web browser on the attached computer and enter the
factory default IP address of the switch in the following format:
http://<IPAddress>
The main screen of the Web-based Management Interface
opens. Select Configuration > IP from the menu.
Use the fields in
Table 16 "IP Configuration fields" (page 87)
configure the IP parameters.
Click Apply.
Description
The mode for bootstrap protocol requests.

ERS 5000 Series Installation

NN47200-300 04.03
13 April 2009
IP address information configuration 87
--End--