GE Corometrics 250cx Series Operator's Manual page 137

Hide thumbs Also See for Corometrics 250cx Series:
Table of Contents

Advertisement

Annotation
CARDIO INOP
UA INOP
MSpO
2
Chart Speed
(Example: 3 cm/min)
UA REF
BASELINE PRESSURE OFFSCALE
Maternal NIBP vital signs data. For example:
NIBP 103/ 71 M 83 P 72 (mmHg mode)
NIBP 13.7/9.5 M 11.1 P 72 (kPa mode)
or
NIBP 103/ 71 M 83 P 72 (mmHg mode)
NIBP 13.7/9.5 M 11.1 P 72 (kPa mode)
NIBP (D)
MSpO
vital signs data. For example:
2
MSpO
97% P 66
2
or
MSpO
98% P 70
2
Revision C
Recorder Modes: Summary of Annotations
Summary of Annotations (Continued)
This annotation prints in place of any trend source if the respective connector
(FECG/MECG, US, or US2) is unused.
This annotation prints in place of the trend source if the UA receptacle is unused.
INOP
This annotation prints if the trend is enabled and the Maternal SpO
unused.
The chart speed prints on the bottom annotation line 20 seconds after you turn
on the monitor.
This message prints on the bottom line of the bottom strip chart paper grid during
active uterine activity monitoring whenever:
you press the UA Reference button; or
whenever automatic re-zeroing occurs during tocotransducer monitoring.
This annotation prints on the bottom line of the bottom strip chart paper grid
during IUPC monitoring when the pressure falls below 0 mmHg for more than 20
seconds.
Maternal NIBP vital signs data prints for each manual and automatic
determination.
identifies an external device as the source.
The diamond prints on the bottom two lines of the bottom grid of the strip chart
paper and marks the time of the reading. The vital signs data prints in one of the
top three lines of the annotation area as soon as a printing line is available. The
printed pulse rate value is derived from the blood pressure parameter and is
independent of the MHR/P source selected on the MHR/P Setup screen.
Indicates an NIBP determination was cancelled or delayed due to the
occurrence of a uterine contraction.
MSpO
Setup screen (built-in parameter) or the General Setup screen (external device).
In addition, for the built-in parameter only, vital signs data is printed when a
MSpO
minute period.
identifies an external device as the source.
The diamond prints on the bottom two lines of the bottom grid of the strip chart
paper and marks the time of the reading. The vital signs data prints in one of the
top three lines of the annotation area as soon as a printing line is available. The
printed pulse rate value is derived from the pulse oximetry parameter/monitor
and is independent of the MHR/P source selected on the maternal MHR/P Setup
screen.
250cx Series Maternal/Fetal Monitor
2036946-001
Explanation
identifies the 250cx Series as the source.
vital signs data is printed at selected intervals according to the MSpO
2
alarm occurs; however, only one alarm-related print occurs within a 5-
2
identifies the 250cx Series as the source.
receptacle is
2
2
11-11