• Once the pump has been released, open
the gas cock and check that the boiler op-
erates correctly both in domestic hot water
and heating modes.
• Check the gas pressures and flow rates as
shown in section "GAS CONVERSION" on
page 63 of this booklet.
• Check that the condensate produced during
functioning fills the syphon and is regularly
drained in the draining pipe.
Automatic air venting function
• Enter "programming mode" by pressing the
11 and 13 keys simultaneously for 5 sec-
onds (Fig. 7.4) until HiS (Boiler History) ap-
pears on the LCD display (Fig. 7.6).
Fig. 7.6
• Scroll through the various menus by press-
ing the keys 11 (back) or 13 (forward), until
APU (Automatic air venting function) ap-
pears on the LCD display (Fig. 7.7).
Fig. 7.7
• Press the 12 key to activate the function.
The display will show the following (Fig. 7.8
and Fig. 7.9).
- 48 -
COMMISSIONING
Fig. 7.8
Fig. 7.9
• At the end of the procedure, the display will
show the following (Fig. 7.10).
Fig. 7.10
To exit the parameters menu:
• wait 15 minutes without pressing any key;