● Permanent database of operational and functional information from the moment that the
● New firmware updates can be downloaded from the Siemens internet portal for Product
8.10

Simulation

Simulation is used for testing purposes, typically for checking that the readings of the control
system are correct.
The simulation can be activated in LUI (menu item 3.7) or via SIMATIC PDM in the
parameter "Enable Simulation" (EnableSimulation).
Inputs/outpus simulation
Depending on the configutration of each input/output the following values can be simulated:
Table 8- 5
HW
configuration
Current output
Relay output
Signal input
Signal output
Process value simulation
The following process values can be simulated:
● Massflow
● Volumeflow
● Corrected Volumeflow
● Density
● Process Media Temperature
● Fraction A %
● Fraction B %
Enabling simulation for the process values sets the simulated value for all outputs.
SITRANS FC430 with HART
Operating Instructions, 03/2012, A5E03361511-01
flowmeter is switched on
Support and stored on SensorFlash (unmounted from the transmitter and inserted into a
PC's SD card slot). The firmware is then loaded from the SensorFlash into the existing
flowmeter and the complete system upgraded
Inputs/outputs simulation
Channel 1
Current
Pulse
Frequency
Status
Channel 2
Channel 3
8.10 Simulation
Channel 4
Simulation value
4 to 20 mA
0 (low) or 1 (high)
0 (low) or 1 (high)
0 to 25 mA
0 to 12.5 kHz
0 to 12.5 kHz
0 (low) or 1 (high)
Functions
137