Table 12- 13 Process media conditions
Description
Process media temperature (T
Process media density (min to max) [kg/m
Process media gauge pressure (min to max) [bar]
Process media absolute pressure (min to max) [bar]
Process media viscosity
Pressure drop
Pressure temperature ratings
12.7

Pressure drop curves

The pressure drop is dimension dependent and influenced by process media viscosity and
density.
Pressure drop information is available on request
12.8

Pressure - temperature ratings

Table 12- 14 EN1092-1:2008-09
PN (bar)
16
40
63
100
Table 12- 15 ISO228-G and ASME B1.20.1 NPT
PN (bar)
100
SITRANS FC430 with HART
Operating Instructions, 03/2012, A5E03361511-01
) (min to max) [°C]
s
-50
0
16.0
16.0
40.0
40.0
63.0
63.0
100.0
100.0
-50
0
100.0
100.0
Specification
-50 to +200
]
1 to 5000
3
0 to 100
1 to 101
Gases and non-compressible liquids
See "Pressure drop curves"
(Page 167)
See "Pressure - temperature ratings"
(Page 167)
Temperature TS (°C)
50
100
16.0
15.2
40.0
37.9
63.0
59.7
100.0
94.8
Temperature TS (°C)
50
100
100.0
100.0
Technical data
12.7 Pressure drop curves
150
200
13.8
12.7
34.5
31.8
54.3
50.1
86.2
79.5
150
200
100.0
100.0