Checklist B Procedures

B-1
Check the Engine Choke -
Gasoline/LPG Models
Note: Genie requires that this procedure be
performed every 250 hours or quarterly, whichever
comes first.
A properly functioning choke is essential to good
engine performance. An improperly functioning
choke will result in difficulty with engine starting.
Note: The manual choke is solenoid operated and
is only operational in the gasoline mode. This
choke will not operate in propane mode.
1 Check the choke linkage connections.
+
a
choke solenoid
b
linkage lock nuts
3 - 16
2 Turn the key switch to ground control and then
pull out the ground control red Emergency Stop
button to the on position.
3 While operating the choke switch, inspect the
choke solenoid.
Result: The choke solenoid should be fully
retracted when the choke switch is activated.
4 Turn the key switch to platform control.
5 Pull out the platform control red Emergency
Stop button to the on position and then operate
the choke switch and listen for choke solenoid
operation.
a
b