Basic setting of control (Advanced)
Basic setting
Generator mode
Steam elimination
Time format
Format for cooking
program times
Parameter
Standard
s
value
45
0
48
1
675
0
676
0
Installation instructions
Range of
Explanation
adjustment
0 = No
When a generator is used to supply
electricity
1 = Yes
0 = Low
Sets the steam elimination level
1 = Normal
2 = High
0 = 24 h
Set the 12-h or 24-h time format
1 = 12 h
0 = hh:mm
Display format for cooking program times
1 = mm:ss
2 = automatic
Description of the unit
17