5560A/5550A/5540A
Operators Manual
Number
VI AUX (3.1 A Current OUTPUT) terminal
A
when ≤ 3.1 A is selected.
B
OUTPUT LO terminal
Volts/Impedance (VZ) OUTPUT HI terminal
C
capacitance and inductance sourcing, and Resistance Temperature Detector (RTD)
simulation.
Volts/Impedance (VZ) SENSE HI terminal
compensation in impedance functions, use the Volts/Impedance (VZ) SENSE terminals to
sense at the DUT.
D
Use external sensing in the voltage functions when the DUT draws enough current to
produce a significant voltage drop in the cables, and in the impedance functions when the
DUT has a four-wire input. External sensing is also used for two-wire compensation in
impedance functions to allow compensation to the DUT terminals.
E
SENSE LO terminal
30A terminal
F
selected (>3.1 A to 30.2 A).
10
Table 4. Front-Panel Features
[1] [2]
[1] [2]
[1]
- The 30 A terminal is the source of current output when the 30 A range is
Description
[1]
- This terminal is the source of current output
[1]
-Terminal for ac and dc voltage, resistance,
[1]
- In voltage functions, or 2-wire / 4-wire