Printing the calibration chart
If the calibration chart is not at hand, you can print it using these steps.
Steps
St
1.
Press [Print Calibration Chart] on the [Scan Sensor Gap Calibration] screen.
2.
Select paper tray, and press the <Start> button on the
1
control panel.
Note
The calibration chart is printed out.
1.10.2
If you are not satisfied with the result of Auto Adjust, you can perform the calibration manually.
Up to three adjustment values derived from the calibration can be registered to the machine.
Step 1: Registering adjustment values
Steps
St
1.
Press [Option Adjust] on the [Scan Sensor Gap Calibration] screen.
2.
Select [Adjustment Value1], [Adjustment Value2], or
[Adjustment Value3].
Note
3.
Press [Edit].
1.10 Calibrating the Scan Sensor Gap
58
The sizes of paper loaded in the trays are
displayed. Make sure that you select A0 (841
mm) or larger size paper.

Performing Optional Adjustment

If you choose not to register these adjustment
values, select [Off].