9.11 Setting the boiler's chimney
sweep function
With the boiler set to chimney sweep mode,
some automatic boiler functions can be dis-
abled, which makes checking and monitor-
ing operations easier.
• Enter "programming mode" by holding
down 17 and 18 for 5 seconds at the same
time (Figure 9.15). The code P00 appears
on the display, indicating entry into "pa-
rameter P00" (Figure 9.16).
- 66 -
MAINTENANCE
12
13
Figure 9.15
Figure 9.16
Chimney sweep function at minimum
output in domestic hot water mode
• Scroll through the various parameters us-
ing 12 or 13 until the LCD display shows
the code P06, indicating entry into "pa-
rameter P06" (Figure 9.17).
Figure 9.17
• Press 16 (Figure 9.15) to show the value
of parameter P06 on the LCD display (Fig-
ure 9.18).
Figure 9.18