Figure 9.29
• Press 12 and hold until the LCD display
shows the code P09, indicating entry into
"parameter P09" (Figure 9.30).
Figure 9.30
• Use 15 or 16 (Figure 9.23) to change the
value of parameter P09 (Figure 9.31).
03 = Default
01 = Correct
Figure 9.31
• Press 12 or 13 (Figure 9.23) to confirm the
value entered and return to the list of pa-
rameters (Figure 9.28).
• Press 12 and hold until the LCD display
shows the code A01, indicating entry into
"parameter A01" (Figure 9.32).
MAINTENANCE
RESET
bar
RESET
bar
RESET
bar
Figure 9.32
• Use 15 or 16 (Figure 9.23) to change the
value of parameter A01 (Figure 9.33).
00 = Methane gas (G20)
01 = Propane gas - LPG (G31)
Figure 9.33
• Press 12 or 13 (Figure 9.23) to confirm the
value entered and return to the list of pa-
rameters (Figure 9.32).
• Press 12 and hold until the LCD display
shows the code A02, indicating entry into
"parameter A02" (Figure 9.34).
Figure 9.34
• Use 15 or 16 (Figure 9.23) to change the
value of parameter A02:
01 = high temperature (50/80°C)
02 = low temperature (25/55°C)
03 = complete temperature set (25/85°C)
(factory setting)
• Press 12 or 13 (Figure 9.23) to confirm the
value entered and return to the list of pa-
RESET
bar
RESET
bar
RESET
bar
- 69 -