3

USEFUL TIPS

3.1 Filling the heating circuit

Heating circuit
filling cock
Figure 3.1
Access INFO mode by pressing and holding
18 (Figure 3.2) for 5 seconds until the code
n02 shows on the display (Figure 3.3).
18
12
13
Figure 3.2
Figure 3.3
Press 12 (increase) to scroll through the
- 14 -
USEFUL TIPS
CLOSED
OPEN
17
16
15
14
RESET
bar
values until the code n10 "heating water
pressure" and a pressure value of 1.3 bar
(Figure 3.4) appear on the display.
Figure 3.4
Open the filling cock in Figure 3.1 located
under the boiler and at the same time check
the heating circuit pressure on the display.
The pressure must be between 1 bar and
1.5 bar (Figure 3.4).
When the operation is complete, close the
filling cock and bleed any air from the ra-
diators.
Press 17 and hold for 5 seconds to exit
INFO mode (Figure 3.2).

3.2 Heating

For rational and economical service, have a
room thermostat installed.
Never turn off the radiator in the room where
the room thermostat is installed.
If a radiator (or convector) does not heat up,
check if there is any air in the system and
make sure that the cock is open.
If the room temperature is too high, do not
adjust the radiator cocks but decrease the
heating temperature setting using the room
thermostat or the heating control buttons 15
and 16 (Figure 3.5).