Biasi RINNOVA COND 24S User Manual And Installation Instructions page 68

Hide thumbs Also See for RINNOVA COND 24S:
Table of Contents

Advertisement

18
12
13
Figure 9.23
Figure 9.24
• Scroll through the various parameters us-
ing 12 or 13 until the LCD display shows
the message Cod, indicating entry into
"parameter Cod" (Figure 9.25), and then
displays three dashes "- - -".
Figure 9.25
• Press 16 to set "2 -°-", then press 12 to
confirm the 2 and go to the next segment.
• Press 16 to set "2°7 -", then press 12 to
confirm the 7 and go to the next segment.
• Press 16 to set "2°7°5", then press 12 to
confirm the 5 and go back to the list of pa-
rameters.
• The code P10 appears on the display, in-
dicating entry into "parameter P10" (Fig-
ure 9.26).
- 68 -
MAINTENANCE
17
16
15
RESET
bar
RESET
bar
Figure 9.26
• Use 15 or 16 (Figure 9.23) to change the
value of parameter P10 (Figure 9.27):
03 = M275V.2024 SM
04 = M275V.2428 SM
05 = M275V.2832 SM
Figure 9.27
• Press 12 or 13 (Figure 9.23) to confirm the
value entered and return to the list of pa-
rameters (Figure 9.26).
• Press 12 or 13 and hold until the LCD dis-
play shows the code P02, indicating entry
into "parameter P02" (Figure 9.28).
Figure 9.28
• Use 15 or 16 (Figure 9.23) to change the
value of parameter P02 (Figure 9.29).
78 = Default
83 = Correct
RESET
bar
RESET
bar
RESET
bar