18
12
13
Figure 8.3
• The code A01 appears on the display, in-
dicating entry into "parameter A01" (Fig-
ure 8.4).
Figure 8.4
• Use 15 or 16 (Figure 8.3) to change the
value of parameter A01 (Figure 8.5).
00 = Methane gas (G20)
01 = Propane gas - LPG (G31)
Figure 8.5
• Press 12 or 13 (Figure 8.3) to confirm the
value entered and return to the list of pa-
rameters (Figure 8.4).
• Press 17 (Figure 8.3) to exit "program-
ming mode".
• Calibrate the gas valve according to the
instructions in section "CHECKING THE
GAS SETTING" on page 55.
- 60 -
GAS CONVERSION
17
16
15
RESET
bar
RESET
bar
• Reposition the control panel and reas-
semble the front panel of the body.
• Apply the label indicating the type of gas
and the pressure value for which the unit
is set. The self-adhesive label is included
in the conversion kit.