Visual Inspection Of Appliance; Checking The Gas Supply Pressure; Water Inhibitor Concentration; Setting The Boiler Chimney Sweep Function - Biasi Activ A Plus 30C User Manual And Installation Instructions

Sealed chamber fan flue gas boilers
Table of Contents

Advertisement

Unscrew the plug to clean inside the pipe.
Fig. 9.18

9.13 Visual inspection of appliance

Visually inspect all water joints, seals and
connections for any evidence of leakage and
retighten, grease or replace them as neces-
sary.
9.14 Checking the gas supply pres-
sure
Check appliance for gas tightness.
Recheck operational pressures as described
in section "Checking the gas supply pressure"
to page 60 of this manual.

9.15 Water inhibitor concentration

Where chemical products are used the level
of water treatment should be checked on an
annual basis and re treated after full or partial
drain down.
A conductivitymeter can be used to check the
correct concentration of inhibitor in the heat-
ing water.
MAINTENANCE
9.16 Setting the boiler chimney
With the boiler set in chimney sweep mode, it
is possible to exclude some boiler automatic
functions making check and control opera-
tions easier.
40
• Enter in "programming mode" by pressing
keys 14 - 17 - 18 (Fig. 9.19) for 10 seconds
at the same time until the letters P01 are
displayed on the LCD display, indicating that
"parameter 01" (Fig. 9.20) has been acti-
vated.
11
12
13
Fig. 9.19
Fig. 9.20
Chimney sweep function at minimum out-
put in domestic hot water mode
• Press keys 17 and 18 (Fig. 9.19) at the
same time until the LCD display displays
the letters LP that alternate with the heating
water temperature value (e.g.45), indicating
the activation of the "chimney sweep func-
tion" at minimum output (Fig. 9.21).
sweep function
14 15
19
18
17
16
- 81 -