Mounting Kit Assembly (Quarter Turn Actuator) - GEM 1235 Operating Instructions Manual

Electrical position indicator
Table of Contents

Advertisement

10.3 Mounting kit assembly on electrical position indicator
Do not scratch the spindle!
▶ A damaged spindle surface may cause failure of the travel sensor.
Pretensioned spring!
▶ Damage to the device.
Slowly release the tension in the spring.
1
2
1. Pull out spindle 1 as far as it will go.
2. Push spring 2 over spindle 1.
3. Mount operating spindle 3.
4. Push in spindle 1 until it pushes against spring 2.
10.4 Assembling the adapter (linear actuator)
With some mounting kits it is necessary to install an adapter as well. This adapter is enclosed with the required mounting kits.
Valves with a normally open and double acting control function (code 2+3) also include additional O-rings (1+2).
1. Move the actuator to the closed position.
2. Place O-rings 1 and 2 into adapter 3.
3. Screw adapter 3 into the actuator opening as far as it will go and tighten.

10.5 Mounting kit assembly (quarter turn actuator)

4
5
1. Adjust the mounting bracket to the required borehole pattern.
ð To do this, loosen the side screws 5 and set the retaining feet onto the thread of the actuator, and install it using screws
4.
2. Secure the bracket 3 to the retaining feet as shown. In doing so, the tap shaft must sit free of play in the shaft of the actu-
ator.
www.gemu-group.com
CAUTION
CAUTION
3
1
3
2
3
4
5
A
15 / 26
10 Assembly and installation
GEMÜ 1235
24V / IO-Link, 3E, 4E

Advertisement

Table of Contents
loading

This manual is also suitable for:

12361436 eco

Table of Contents