Nortel Business Communications Manager 450 Installation Manual page 102

Hide thumbs Also See for Business Communications Manager 450:
Table of Contents

Advertisement

102 Troubleshooting
Figure 18 Reset switch location
If the reset button is pressed for less then 5 seconds, the BCM will begin the
reboot process. The reboot is completed in less then 30 seconds.
If you hold the BCM450 Reset Button for 5 seconds or more, the BCM450 will
immediately reboot. Data loss may occur. This should only be utilized when
the BCM450 is not responding to normal reboot operations or is entirely non-
responsive. If the BCM450 system has been shut down from the CLI, the
BCM450 Reset Button must be held for 5 seconds to initiate the reboot
process.
After the restart is completed, the BCM450 will wait up to 10 seconds for you
to log onto the BCM Maintenance CLI. If you do not log onto the Maintenance
CLI after 10 seconds, the BCM boots automatically to the Main OS.
Copyright © 2006-2009 Nortel Networks
Reset switch
Nortel Business Communications Manager 450 1.0
Installation — System
NN40160-301 01.04 Standard
July 2009

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bcm450

Table of Contents