To Verify Lan Communications - HP E3491A Installation And Service Manual

Pentium probe
Table of Contents

Advertisement

Setting Up LAN Communication

To verify LAN communications

Set the configuration switch S6 back to 1, then power down the
probe. When the probe is powered down and then powered up, it
will be configured for the new LAN parameters.
To verify LAN communications
Verify your HP E3491A Pentium Probe is now active and on the network by
starting a user session on the prototype analyzer.
1 Drag the uP Control Tool from the toolbox to the workspace.
2 Move the mouse cursor over the uP Control Tool in the workspace, press and
hold the right mouse button, move the cursor over Start Sys Admin Session...,
and let up on the right mouse button.
3 Select the Verify Host Name Address menu to verify that the address is what
you set. If the address is the same, then the parameters have been set.
4 Click the Start User Session. If no error message appears, then
communication is established.
If You Have Problems
If you encounter problems, refer to the "Problems" chapter (page 39).