No target system power, or HP E3491A Pentium Probe is not connected to
the target system, or
Target system is in a reset state
Only the boot ROM was used; other firmware in the Flash EPROM has
been corrupted
Starting a user interface will change the pattern to the one requested
by the interface.
If the power up self tests fail, try the following:
Check and reset the LAN address as shown in the "Connecting to the H
P 16505A Prototype Analyzer" chapter. LAN powerup failures will occur
if the HP E3491A Pentium Probe does not have a valid Link Level
Address and IP Address.
Disconnect all external connections, including the LAN, serial (RS-232),
and BNC Break and Trigger cables, then cycle power.
To ensure that the firmware is working as it should, reprogram the
firmware, then cycle power.