26-6
Purpose
Setup
Function (Content)
Used to set the specification according to the
destination.
Section
Item
Spec
Operation/Procedure After setting the destination, the power is turned
off/on.
*
When NIC is installed, reset cannot be performed. Therefore, the
power must be turned off/on.
*
This simulation cannot change the FAX destination. Use SIM 66-2 to
change the FAX destination.
SIMULATION 26-6
DESTINATION SETUP. SELECT 1-10, AND PRESS START.
1. USA
2. CANADA
3. INCH
4. JAPAN
5.AB _B
6. EUROPE
7. UK
8. AUSTRALIA
9. AB_A
10. CHINA
<List of destinations>
1
United States of America
2
Canada
3
Inch series EX
4
Japan
5
AB series B5
6
Europe
7
UK
8
Australia
9
AB series A5
10
China
26-10
Purpose
Setup
Function (Content)
Used to set the trial mode of the network
scanner.
Section
Item
Operation
Operation/Procedure The network scanner trial mode is set.
(Testing scanner without product key is limited to
500 sheets.) (Default: 0)
SIMULATION 26-10
NETWORK SCANNER TRIAL SETTING. SELECT 0-1, AND PRESS
START.
0.END
1.START
<List of set values>
0
Trial mode cancel
1
Trial mode start
26-18
Purpose
Function (Content)
Section
Item
Operation/Procedure The toner mode setup is made. (Default: 1)
SIMULATION 26-18
TONER SAVE MODE SETTING. SELECT 0-1, AND PRESS START.
0. YES
1
1. NO
<List of set values>
0
Toner save mode is enabled.
1
Toner save mode is disabled.
26-30
Purpose
Function (Content)
Section
Item
Operation/Procedure
SIMULATION 26-30
CE MARK CONTROL SETTING. SELECT 0-1, AND PRESS START.
0. NO
1. YES
<List of set values>
0
No control of CE mark
1
Control of CE mark
26-35
Purpose
Function (Content)
1
Section
Item
Operation/Procedure The trouble memory storing method is set.
SIMULATION 26-35
TROUBLE MEMORY MODE SETTING. SELECT 0-1, AND PRESS
START.
0. ONCE
1. ANY
<List of set values>
0
Only once (If same as the previous one, it is not stored.)
1
Any times (Though same as the previous one, it is stored.)
AR-M350 SIMULATIONS 10-29
Setup
Used to set Enable/Disable of toner save
operation.
(This simulation is enabled only in Japan and UK
versions. (Depends on SIM 26-6 (Destination)
setup).
For the other destinations, user program P22
allows to make the similar setup.)
Spec
Setup
Used to set the operation mode conforming to
the CE mark (Europe standards). (For flickers
when driving the fusing heater lamp.)
Spec
Setup
Used to set whether the trouble history of SIM
22-4 is displayed as one-time trouble or
continuous troubles when two or more number of
a same trouble occurred.
Spec
(Default: 0)
1
1