Original width detection volume installation
<1>Extend the original guide to the maximum position.
<2>Adjust so that the mark on the width detection pinion gear is fitted
with the mark on the volume mounting plate.
<3>Fix the mounting plate with the screw.
*
When the rotational volume sensor is replaced, the sensor value
must be adjusted to the paper size (mark on the tray).
(Refer to the SIM 53-6 or 53-7.)
g. Original paper feed unit
1) Remove the OC cover.
2) Remove the SPF lower cover.






AR-M350 DISASSEMBLY AND ASSEMBLY, MAINTENANCE 7-10
3) Remove the original paper feed unit.




h. Take-up roller, paper feed roller
1) Remove the upper transport unit cover.
2) Remove the paper feed roller cover.
3) Remove the hook of each roller, and remove each roller.

i. CIS unit
1) Remove the upper transport unit cover.
2) Remove the CIS unit.

*
When the CIS unit is replaced, the CIS shading adjustment must be
performed. (Refer to the descriptions of ADJUSTMENTS.)



!



"
!