Sharp AR-M350U Service Manual page 163

Options ar-p14
Hide thumbs Also See for AR-M350U:
Table of Contents

Advertisement

Main code 14
Purpose
Cancel (in case of a trouble)
Function (Content)
Used to cancel the self diag U1/LCC/US/PF
troubles.
Section
Item
Trouble
Operation/Procedure Select with 10 digit key pad
SIMULATION 14
TROUBLE CANCELLATION. (OTHERS)
ARE YOU SURE ?
1. YES
2. NO
<List of set values>
1
After canceling a trouble other than U1, U2, PF, and LCC,
the display returns to the main code entry menu.
2
Without canceling a trouble, the display returns to the main
code entry menu.
Main code 15
Purpose
Cancel (incase of a trouble)
Function (Content)
Used to cancel the self diag "U6 (09/20/21/22)"
trouble.
Section
Paper feed
Item
Trouble
Operation/Procedure Select with 10 digit key pad.
SIMULATION 15
LCC TROUBLE CANCELLATION.
ARE YOU SURE ?
1. YES
2. NO
<List of set values>
1
After canceling LCC trouble, the display returns to the main
code entry menu.
2
Without canceling a trouble, the display returns to the main
code entry menu.
Main code 16
Purpose
Cancel (incase of a trouble)
Function (Content)
Used to cancel the self diag "U2" trouble.
Section
Item
Trouble
Operation/Procedure Select with 10 digit key pad.
SIMULATION 16
U2 TROUBLE CANCELLATION.
ARE YOU SURE ?
1. YES
2. NO
<List of set values>
1
After canceling U2 trouble, the display returns to the main code
entry menu.
2
Without canceling a trouble, the display returns to the main
code entry menu.
Main code 17
Purpose
Function (Content)
Section
Item
Operation/Procedure Select with 10 digit key pad.
SIMULATION 17
PF TROUBLE CANCELLATION.
1
ARE YOU SURE ?
1. YES
2. NO
<List of set values>
1
After canceling PF trouble, the display returns to the main code
entry menu.
2
Without canceling a trouble, the display returns to the main
code entry menu.
Main code 21
21-1
Purpose
Function (Content)
Section
Item
Operation/Procedure Used to set the maintenance cycle in an SRU
1
SIMULATION 21-1
MAINTENANCE CYCLE SETUP. SELECT 0-6, AND PRESS START.
0. DEFAULT
4. 100K
<List of set values>
0
Maintenance display at the cycle of each control spec.
1
Maintenance display at 40K
2
Maintenance display at 50K
3
Maintenance display at 80K
4
Maintenance display at 100K
5
Maintenance display at 120K
6
No maintenance display
1
AR-M350 SIMULATIONS 10-19
Cancel (incase of a trouble)
Used to cancel the self diag "PF" trouble
(when copy is inhibited by the host computer).
Communication (RIC/MODEM)
Trouble
Setup
Used to set the maintenance cycle.
Spec
machine.
1. 40K
2. 50K
3. 80K
5. 120K
6.FREE
1
1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ar-m450uAr-m350nAr-m450n