Code
Main Sub
66
1
Used to set the FAX soft switch function. (Used to utilize the
FAX soft switch function.)
2
Used to set the FAX soft switch setup to the default.
(Except for the adjustment values)
3
Used to check the operations of FAX PWB memory
(read/write). (This adjustment is required when replacing the
PWB with a new one.)
4
Used to check the operations of data signal output in the FAX
data output mode.
(Used to check the MODEM operation.)
Send level 0dB (Max.) (Only when FAX is installed.)
5
Used to check the operations of data signal output in the FAX
data output mode.
(Used to check the MODEM operation.)Signals are sent in the
send level set with the soft switch. (Only when FAX is installed.)
6
Used to print the confidential password.
(Used when the confidential password is forgotten.)
(Only when FAX is installed.)
7
Used to print the image memory data (memory send, receive).
(Only when FAX is installed.)
8
Used to check the output operation of the FAX sound signals.
(Sound output IC operation check) Send level 0dB (Max.)
(Only when FAX is installed.)
9
Used to check the output operation of the FAX sound signals.
(Sound output IC operation check)
(Only when FAX is installed.)
10 Used to clear all data of image memory
(memory send, receive). Confidential data are also cleared.
(Only when FAX is installed.)
11 Used to check the output operation of FAX G3 mode 300BPS.
(Used to check the MODEM operation.)
Send level 0dB (Max.) (Only when FAX is installed.)
12 Used to check the output operation of FAX G3 mode 300BPS.
(Used to check the MODEM operation.) Signals are sent in the
send level set with the soft switch. (Only when FAX is installed.)
13 Used to enter (set) the number for the FAX dial signal output
test.
(The dial number signal set with this simulation is outputted in
the dial signal output test with SIM 66-14~16)
(Only when FAX is installed.)
14 Used to set the make time in the FAX pulse dial mode (10PPS)
and to test the dial signal output.
(The dial number signal set with SIM 66-13 is outputted.)
Used to check dialing troubles and the operation.
(Only when FAX is installed.)
Function (Content)
AR-M350 SIMULATIONS 10-7
Purpose
Setup
Fax
Data clear
Fax
Operation test, check
Fax
Operation test, check
Fax
Operation test, check
Fax
User data output, check
Fax
(display, print)
User data output, check
Fax
(display, print)
Operation test, check
Fax
Operation test, check
Fax
User data output, check
Fax
(display, print)
Operation test, check
Fax
Operation test, check
Fax
Setup
Fax
Setup
Fax
Section
Item
Data
Data
Operation
Operation
Data
Data
Operation
Operation
Data
Operation
Operation
Data
Operation

Advertisement