Section 8
Disassembly
Remove Oil Sentry
(On Models So Equipped)
1. Disconnect the lead from the Oil Sentry™
pressure switch.
2. Remove the pressure switch from the center
passage or adapter elbow in the closure plate. See
Figure 8-2. Removing Oil Sentry™ Switch.

Remove Blower Housing

1. Remove the four shoulder screws securing the
blower housing to the closure plate. See Figure
plug lead from the corresponding slot.
Figure 8-3. Removing Blower Housing Screws.
Disconnect Spark Plug Lead
1. Carefully pull on the boot section and disconnect
the spark plug lead.
8.2
Pressure Switch
port.
Figure 8-4. Removing Exhaust Flange Nuts (Stud
Design).
Remove Electric Starter
1. Disconnect the starter lead from the terminal
stud.
starter to the closure plate. Remove the starter.