Zenith HydroTap G5 Installation Instructions Manual page 5

Command centre
Hide thumbs Also See for HydroTap G5:
Table of Contents

Advertisement

SECTION 2: IMPORTANT SAFETY INSTRUCTIONS
Do not store explosive substances such as aerosol cans with a flammable
propellant in this appliance.
Qualifications
To avoid hazards, all installation procedures must be carried out by a
suitably qualified tradesperson. The power cable and power outlet must be
in a safe visible position for connection.
Venting
Sometimes steam and / or boiling water droplets may discharge through a
vent outlet on the tap. If not using the font, ensure the tap body is located
so the tap outlet safely dispenses into the sink bowl.
Lifting
Take care when lifting. The Command Centre may exceed safe lifting
limits. If you feel this is beyond your personal capabilities, please seek
assistance with the lift. The weight of the Command Centre is marked on
the packaging. Do not lift the Command Centre by the front cover or any of
its connections.
Airflow
The ambient operating temperatures, when installed in a cabinet, must be
between 5 - 35ºC. The system will operate satisfactorily only with proper
air ventilation. Air gaps of 50mm on each side, and 200mm above must be
provided.
See section 7 for correct ventilation details.
Altitude
Water boils at varying temperatures at different altitudes. The HydroTap
adjusts for this during startup calibration and will recalibrate itself on a
regular basis.
Frost protection
If the HydroTap is located where the ambient air temperature could fall
below 5
C when the system is not in use, do not turn off the Command
º
Centre electrically. This safeguard does not offer the same protection to
the connecting pipework and fittings.
807042NZ v1.02 08.22 HydroTap G5 UltraCare Install Instructions