UltraCare BCU40
PRODUCT LABEL
Visit our website to
download the manuals
807042NZ v1.00 03.21 HydroTap G5 UltraCare Install Instruct
1

Advertisement

Table of Contents
loading

Summary of Contents for Zenith HydroTap G5

  • Page 1 Installation Instructions Zenith HydroTap G5 Model: UltraCare BCU40 PRODUCT LABEL Visit our website to download the manuals 807042NZ v1.00 03.21 HydroTap G5 UltraCare Install Instruct...
  • Page 2: Table Of Contents

    Zenith HydroTap UltraCare adds anti-bacterial components and an ultraviolet module to eliminate bacteria and other micro-organisms. Due to the process of continuous improvement, Zenith reserves the right to change details mentioned in this manual, without notice. Visit zenithwater. co.nz to ensure you have the latest copy of this document.
  • Page 3: Warnings And Precautions

    When positioning the appliance, ensure the power supply cord is not trapped or damaged. If the power supply cord is damaged it must be replaced by a Zenith service provider or a qualified electrician. 6. Use only the power supply provided with the UV-C Module. An ACM36US21 power supply is provided.
  • Page 4 WARNINGS AND PRECAUTIONS 15. For water taste and quality reasons, following any non-use period of more than 72 hours, Zenith recommends to perform a system flush. Failure to flush the system may affect water quality. Safety This appliance is not intended for use by persons (including children) with reduced...
  • Page 5: Major Components And Accessories

    93303NZ 1 x Inlet, 1 x Outlet, 9x screws Accessibility kit part no. 93257NZ (for Classic Tap) part no. 93143NZ Vent tray kit Dual exhaust fan part no. 93540NZ part no. 93156NZ 807042NZ v1.00 03.21 HydroTap G5 UltraCare Install Instruct...
  • Page 6 The system is only designed to reduce normally occurring non-pathogenic nuisance microorganisms. Class B systems are not intended for treatment of contaminated water. 807042NZ v1.00 03.21 HydroTap G5 UltraCare Install Instruct...
  • Page 7: Before Installation

    Jigsaw and 12mm drill (not supplied) for installation of ventilation. • Keyhole or wall board saw (not supplied) for installation of ventilation. IMPORTANT! Do not proceed with the installation if these requirements are not met. 807042NZ v1.00 03.21 HydroTap G5 UltraCare Install Instruct...
  • Page 8: Installation Instructions

    Filtered water tap (Classic Tap shown) UV-C Module HydroTap Command Centre cut-out Power for UV-C Mains water inlet Vent tray Side duct Module (isolation valve not Mains supplied) power supply to Command Centre 807042NZ v1.00 03.21 HydroTap G5 UltraCare Install Instruct...
  • Page 9: Step 2 - Ventilation

    50 min. 70 min. Additional ventilation will be required. Options include vent grilles and a dual exhaust fan kit. Contact your local service centre for more details. 93156 Dual Exhaust Fan Kit 807042NZ v1.00 03.21 HydroTap G5 UltraCare Install Instruct...
  • Page 10: Step 3 - Tap Installation

    (not included). For good fall of the water hoses, the tap tubes may be shortened using a PVC cutter (conduit cutter). Ensure the cut edges are not sharp, before fitting the hose. 807042NZ v1.00 03.21 HydroTap G5 UltraCare Install Instruct...
  • Page 11: Step 4 - Command Centre Installation

    Command Centre. Mains water connection Flush water supply lines before any plumbing connections are made, to prevent sediment from affecting operation. No Mixer Command Centre MAINS IN Mains water (isolation valve not supplied) 807042NZ v1.00 03.21 HydroTap G5 UltraCare Install Instruct...
  • Page 12 HydroTap. Power must remain OFF until commissioning. Use only the power supply provided. Attach the L-shaped bracket (supplied) with adhesive tape to the power supply to support it against the wall. 807042NZ v1.00 03.21 HydroTap G5 UltraCare Install Instruct...
  • Page 13 The hoses must not be under tension when installed. • Hoses must not be lengthened beyond the maximum supplied 1-metre length. • Ensure the cut edges are not sharp, before fitting the hose. 807042NZ v1.00 03.21 HydroTap G5 UltraCare Install Instruct...
  • Page 14: Step 5 - External Filter Installation (Optional)

    If an external filter is installed, rotate the bypass valve as shown. Refer to the LCD screen to perform a filter flush of at least 10 litres. Without external filter With external filter (factory setting) 807042NZ v1.00 03.21 HydroTap G5 UltraCare Install Instruct...
  • Page 15: Step 6 - Commissioning

    New filter cartridges must be flushed before use. Follow the steps on the screen to flush the filter for approximately 2 minutes. This step cannot be skipped. Once complete, press NEXT. Open valve to let water flow (bucket not Close valve supplied) when complete 807042NZ v1.00 03.21 HydroTap G5 UltraCare Install Instruct...
  • Page 16 10 minutes. Upon completion, the External Booster screen will appear. For best product performance, ensure the correct selection for the booster: • YES: booster is installed, OR • NO: booster is not installed. 807042NZ v1.00 03.21 HydroTap G5 UltraCare Install Instruct...
  • Page 17: Troubleshooting

    Troubleshooting The HydroTap tap lights will flash to indicate when service is required. Refer to the LCD screen in the Command Centre. Call an electrician, a plumber, or Zenith service for assistance, service, spare parts or enquiries. System fault message...
  • Page 18 UV PCB is faulty UV Comms Error Communication b. Ribbon cable connecting No communication restored. the UV PCB and the LCD to the UV IO PCB. PCB is faulty. 807042NZ v1.00 03.21 HydroTap G5 UltraCare Install Instruct...
  • Page 19: Operation & Maintenance

    HydroTap. The User Guide is located in the HydroTap Command Centre filter door. The Zenith filter should be replaced as recommended on the filter, or earlier if you notice a persistent reduction in water flow from the tap or an increase in chlorine, taste or odour in the water.