Zenith HydroTap G5 Installation Instructions Manual page 14

Command centre
Hide thumbs Also See for HydroTap G5:
Table of Contents

Advertisement

Refer to the instructions provided with the Vent Tray.
Cold air is drawn in through the inlet vent and gap provided by the door
buffers.
Inlet vent is mounted over cupboard side, door or floor cut-out.
Warm air is exhausted through vent tray.
Observe 100mm inlet / outlet vent separation.
The supplied vent tray must be fitted. It provides a safe exhaust for
!
refrigerant gas in the unlikely event of a leak.
Air inlet options
4mm door buffers
(supplied)
Vent tray exhaust cut-out
450
Vent tray dimensions WxDxH (mm): 500 x (515-555) x 40
Absolute min. vent tray depth 490mm (limit of travel, may affect airflow).
14
807042NZ v1.02 08.22 HydroTap G5 UltraCare Install Instructions
SECTION 7: Set up the ventilation
100mm
Air outlet
Vent tray
40