Zenith HydroTap G5 Installation Instructions Manual page 26

Command centre
Hide thumbs Also See for HydroTap G5:
Table of Contents

Advertisement

13.7 Select the booster
• Read the on screen instructions.
• Select the appropriate option.
• BCU100 models select Booster installed.
• All other models, Booster not installed.
13.8 Safety sensor calibration
Optional, in cases where light recalibration is required.
Light intensity varies from site to site,
therefore it is recommended that a
re-calibration be performed at the time of
the installation. All direct sunlight must
be shaded from the HydroTap, during the
calibration. This can be achieved by closing
any nearby curtains, blinds, etc.
• Shield the HydroTap from direct sunlight.
• In normal operating mode. Turn the
power off.
• Pull both tap levers to the forward
position.
• Turn the power on.
• The safety sensor will calibrate.
• Return the levers to the neutral
position.
Quick Start Installation Guide
26
807042NZ v1.02 08.22 HydroTap G5 UltraCare Install Instructions
SECTION 13: Commissioning
(Classic boiling models only)
EXTERNAL BOOSTER
Has an external booster been installed ?
Yes
No
installed
Not installed
Pull both levers
forward