6 Technical data

6.1 Temperature
6.2 Product compliance
Explosion protection:
ATEX marking:
Type examination
certificate:
6.3 Mechanical data
Weight:
Protection class:
Range of limit switch:
Mechanical stability:
Max. switching frequency: ≤ 1000 switching cycles/h
6.4 Electrical data
Switch type:
Switch rating:
Thermal rated current:
Electrical connection
type:
www.gemu-group.com
ATEX (2014/34/EU), order code special version X
only for order code Display (code 0)
Gas:
II 2G Ex db eb IIC T6 Gb
Dust:
II 2D Ex tb IIIC T80°C Db
IBExU18ATEX1008
1146.5 g
IP 65 acc. to EN 60529
2 to 70 mm continuous
7 Nm, impact energy acc. to EN 60079-0
Microswitch
Switch rating AC
Voltage
250 V
30 V
Switch rating DC
Voltage
250 V
30 V
Information applies to 40 °C ambient temperature
6 A
M20 cable gland
Cable diameter:
Terminal diameter:
Earth terminal:
Potential equalisation:
Tightening torque
Ohmic load
5 A
7 A
Ohmic load
0.4 A
7 A
1 x available (Type Bartec 03-6020-0016)
1 x prepared (blanking cover)
7 to 13 mm
2.5 mm²
4.0 mm²
Stranded wire, yellow/green, H 07 V-K 4.0
10 Nm
7 / 20
6 Technical data
Inductive load (cosϕ = 0.6)
3 A
5 A
Inductive load (cosϕ = 0.6)
0.03 A
5 A
GEMÜ 1205