8 Manufacturer's information

8.1 Delivery

1. Check that all parts are present and check for any dam-
age immediately upon receipt.
The product's performance is tested at the factory. The
scope of delivery is apparent from the dispatch documents
and the design from the order number.

8.2 Packaging

The product is packed in a cardboard box which can be re-
cycled as paper.

8.3 Transport

1. Only transport the product by suitable means. Do not
drop. Handle carefully.
2. After the installation dispose of transport packing mater-
ial according to relevant local or national disposal regula-
tions / environmental protection laws.

8.4 Storage

1. Store the product free from dust and moisture in its ori-
ginal packaging.
2. Avoid UV rays and direct sunlight.
3. Do not exceed the maximum storage temperature (see
chapter "Technical data").
4. Do not store solvents, chemicals, acids, fuels or similar
fluids in the same room as GEMÜ products and their
spare parts.
www.gemu-group.com

9 Assembly and installation

Risk of electric shock
▶ Risk of injury or death (if operating
▶ Electric shock can cause severe burns
Danger - high voltage!
▶ Electric shock.
Fitted electrical position indicator
▶ Destruction of the electrical position indicator when dis-
assembling the valve body
Disassemble the electrical position indicator before dis-
assembling the valve body
Observe the data on the product labels, product docu-
mentation and the EC type examination certificate.
Connect cable carefully, do not damage individual wires.
Prepare the wire ends when connecting several cables or
fine-wired cables.
Always attach wire end ferrule stops using pinch tools to
achieve consistent quality.
Tighten all clamping points, even the ones not being
used.
9.1 Preparations for assembly to the valve
1. Move the actuator A into zero position (actuator vented).
2. Remove optical position indicator 2 and / or protective
cap 1 from the actuator top.
9 / 20
9 Assembly and installation
DANGER
voltage is higher than safe extra low
voltage).
and fatal injury.
Work on electrical connections only by
qualified trained personnel.
Disconnect the cable from the power
supply before making the electrical
connection.
Connect the protective earth con-
ductor.
CAUTION
Before performing any work on the
GEMÜ product switch off power and
protect circuit from being switched on
again.
CAUTION
NOTICE