Installation
To maintain grounding continuity when flushing or
relieving pressure: hold a metal part of the dispense
valve firmly to the side of a grounded metal pail, then
trigger the valve.
Power Supply
See Table 1 for power supply requirements. The system
requires a dedicated circuit protected with a circuit
breaker.
Table 1: Power Supply Specifications
Voltage
Phase
200-240 VAC
Select the minimum cord wire gauge based on length
according to the table below:
Length
50 ft (15.24 m)
100 ft (30.48 m)
200 ft (60.96 m)
300 ft (91.44 m)
Power Disconnect Switch
A power disconnect switch must be installed within easy
reach of the equipment. This switch must shut off and
lock-out all electric power to the system.
Connect Power
To avoid equipment damage, route and secure a
power cord that is long enough to allow the full range
of movement for the ram.
1. Cut power cord wires to the following lengths:
•
Ground wire - 6.5 inches (16.5 cm)
•
Power wires - 3.0 inches (7.6 cm)
•
Add ferrules as necessary. See F
F
. 4: Power Cord
IG
10
Hz
Current
1
50/60
20 A
2
Gauge
mm
12 AWG
3.31
10 AWG
5.26
6 AWG
13.29
4 AWG
21.14
NOTICE
. 4.
IG
2. Remove the two screws and washers to separate
the junction box cover (BA) and disconnect switch
(K) from the junction box (BC) on the electrical
driver.
BC
BA
F
. 5: Remove Junction Box Cover
IG
NOTE: Inside the junction box, fan and power wires are
connected to terminals 1L1 and 5L3 on the disconnect
block. Refer to F
. 6 for the terminal locations. Two
IG
wires are connected to each terminal and the fan ground
wire is connected to the ground terminal as shown in
F
. 5.
IG
C2
F
. 6: Terminal Connections
IG
3. Press the junction box gasket tightly against the
back of the junction box cover to ease installation of
the power cord.
BD
BA