Ram Troubleshooting - Graco D60 Operation

Electric supply systems for sealants and adhesives
Hide thumbs Also See for D60:
Table of Contents

Advertisement

Ram Troubleshooting

Check all possible problems before disassembling the ram, pump, or platen. Refer to the appropriate pump manual
for pump troubleshooting.
Problem
Ram will not raise or
Closed air valve or
lower.
clogged air line.
Not enough air pres-
sure.
Worn or damaged
piston.
Hand valve closed
or clogged.
Ram raises and low-
Air pressure is too
ers too fast.
high.
Air leaks around cyl-
Worn rod seal.
inder rod.
Fluid squeezes past
Air pressure too
ram plate wipers.
high.
Worn or damaged
wipers.
Pump will not prime
Closed air valve or
properly or pumps
clogged air line.
air.
Not enough air pres-
sure.
Worn or damaged
piston.
Hand valve closed
or clogged.
Hand valve is dirty,
worn, or damaged.
Air assist valve will
Closed air valve or
not hold drum down
clogged air line.
or push plate up.
Not enough air pres-
sure.
Valve passage
clogged.
3A5379B
Cause
Open, clear.
Increase.
Replace. See Supply Unit Repair on page 36.
Open, clear.
Decrease.
Replace. See Supply Unit Repair on page 36.
Decrease.
Replace. See Remove and Reinstall Wipers on page 18.
Open, clear.
Increase.
Replace. See pump manual.
Open, clear. See Platen Maintenance on page 17.
Clean, service.
Open, clear. See Platen Maintenance on page 17.
Increase.
Clean. See Platen Maintenance on page 17.
Ram Troubleshooting
Solution
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

25e07925e08025e08125e082

Table of Contents