Installation

Installation
Installation
Installation
Installation of this equipment involves potentially
hazardous procedures. Only trained and qualified
personnel who have read and who understand
the information in this manual should install this
equipment.
NOTE: For complete Technical Specification
NOTE:
NOTE:
information, see Driver Operation manual.
Power Supply
Supply Requirements

Requirements

Power
Power
Supply
Requirements
Improper wiring may cause electric shock or other
serious injury if work is not performed properly.
Have a qualified electrician perform any electrical
work. Be sure your installation complies with all
local codes and regulations.
See the table below for power supply requirements.
The driver requires a dedicated circuit protected with
a circuit breaker.
Model
Model
Model
Voltage
Voltage
Voltage
24X901
200–240
Vac
NOTE: The protective earthing ground conductor
NOTE:
NOTE:
must be equal to the phase conductions..
8
Phase
Phase
Phase
Hz
Hz
Hz
kVA
kVA
kVA
1
50/60
2.5
Hazardous Area
Hazardous
Hazardous
Area Cabling
Area
Requirements
Requirements
Requirements
Explosion Proof
Proof
Explosion
Explosion
Proof
All electrical wiring in the hazardous area must be
encased in Class I, Division I, Group D approved
explosion-proof conduit. Follow all National, State,
and Local electric codes.
A conduit seal is required within 18 in. (457
mm) of the driver for the US and Canada. See
Connect Power, page
10.
All cables must be rated 70°C minimum.
Flame Proof
Flame
Flame
Proof (ATEX)
Proof
(ATEX)
(ATEX)
Use appropriate conduit, connectors, and cable
glands rated for ATEX II 2 G. Follow all local codes
and regulations.
All cable glands and cables must be rated 70°C
minimum.
Cabling and
Cabling
and Conduit
and
Conduit
Conduit
3A3165H