Driver Setup
1. Pull the driver pressure adjustment knob (AK) out
and turn counterclockwise until it stops. Push the
knob in to lock.
F
. 12: Driver Pressure Adjustment Knob
IG
2. Turn the disconnect switch (K) OFF. Connect the
unit to the power source. See F
Mechanical Setup
1. Fill the displacement pump wet cup 2/3 full with
Graco Throat Seal Liquid (TSL).
2. Back-off the air regulator to its full counterclockwise
position and close all shutoff valves.
3. Connect the air line from an air source to the system
air inlet. See F
. 1. Use a supply hose capable of
IG
meeting the required flow.
3A5379B
AK
ti20171a_1
. 5, page 10.
IG
Pump Operation
The driver will adjust the speed to maintain a constant
fluid pressure.
Pull the driver pressure control knob (AK) out to set.
Turn the knob clockwise to increase the pressure, or
counter-clockwise to decrease the pressure. Push the
knob to lock. See F
. 12.
IG
Driver Setup
13