b. Drive sleds (see "Drive Sled" on page 8-43)
4. Loosen the thumb screws securing the library to the rear flange on each Rack
Kit rail.
5. Open the I/O Station door then the Access door on the control module.
6. From the front of the control module, remove the rack ears (see "Removing the
Rack Ears" on page 8-20).
7. With a person standing on each side of the library, pull the control module out
of the rack.
8. Place the library on a sturdy work surface.

Replacing a 5U Library (Control Module) in a Rack

1. With a person on each side of the library, pick it up from the work surface and
slide it onto the Rack Kit rails in your rack.
2. Tighten the thumb screws that secure the library to the rear flange of each Rack
Kit rail.
3. Install the rack ears on the front of the library to secure it to the rack (see
"Replacing the Rack Ears" on page 8-21.
4. Reconnect the customer-supplied Ethernet cable to the Library Control Blade
( 2 in Figure 8-49 on page 8-47).
5. Reinstall the following components removed for weight reduction.
a. Drive sleds (see "Drive Sled" on page 8-43)
b. Power supplies (see "Power Supply (Primary and Redundant)" on page
8-52)
6. Perform "Returning a Library or Library Module to Normal Operations after
Repairs" on page 8-4.
Removing a Control Module from a Standalone or
Rack-mounted Library (14U or larger)
1. Perform "Preparing a Library or Library Module for Repairs" on page 8-4.
Chapter 8. Add, Check, Adjust, Remove, and Replace Procedures
8-5