T129: Drive Sled Firmware Image Error; T130: Tape Drive Cleaning Failure; T132: Hardware Clock Failure; T133: Barcode Label Mapping Failure - IBM TS3310 Maintenance Information

System storage tape library
Hide thumbs Also See for TS3310:
Table of Contents

Advertisement

T129: Drive Sled Firmware Image Error

Description
Detection Scenario
Root Causes
Possible FRUs
Resolution

T130: Tape Drive Cleaning Failure

Description
Detection Scenario
Root Causes
Possible CRUs
Resolution

T132: Hardware Clock Failure

Description
Detection Scenario
Root Cause
Possible CRUs
Resolution

T133: Barcode Label Mapping Failure

Description
GUI Description: Drive sled firmware cannot be auto-leveled due to a
missing or corrupt drive sled firmware image.
Explanation: During an attempt to autolevel the drive sleds, the library
detected a missing or corrupt UDS.lif (drive sled firmware) file.
Main Library Firmware that controls and performs drive sled firmware
updates detects that the drive sled firmware update file is missing or
corrupted.
The drive sled firmware update file is missing or corrupted.
Library firmware
Perform "DR095: Resolve Drive Sled Auto-level Failure" on page 6-89.
GUI Description: A tape drive was cleaned but continues to request cleaning.
Explanation: After a drive was cleaned and the cleaning tape was removed
from the drive, the drive continues to request cleaning.
A drive continues to request cleaning after successful cleaning cycles have
been applied.
Tape drive malfunction.
Drive Sled.
Perform "DR096: Resolve Drive Cleaning Failure" on page 6-89.
GUI Description: The hardware real-time clock (RTC) has failed. The library
system time may appear to be set correctly, but accurate time will be lost
following a power cycle or reboot.
Explanation: While setting the library time, the library detected an error in
the hardware real-time clock (RTC). This type of error will allow the library
system time to be changed, but the time will not be set correctly following a
power cycle or reboot.
Main library firmware determined that setting the hardware clock failed,
though the system time may appear to have been set correctly.
The hardware clock on the LCB has failed.
LCB
Perform "DR098: Resolve Hardware Clock Failure" on page 6-89.
GUI Description: The library control firmware cannot map barcode labels to
respective slots during an inventory operation.
Explanation: The library is attempting to map barcode labels during
inventory and is being prevented from doing so because one or more
barcode labels are improperly attached, or a magazine is improperly
seated/installed.
Chapter 6. Service Action Tickets (Txxx) and Diagnostic Resolutions (DRxxx)
6-53

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents