Platform Overload System - Terex SX135H-101 Service And Repair Manual

Hide thumbs Also See for SX135H-101:
Table of Contents

Advertisement

October 2016
11 Press the enter or previous button on the
LCD screen until EXIT is displayed.
12 Press the plus button or minus button to
select YES and then press the enter button.
13 Remove the fastener that was temporarily
installed. Close the control box door and
install the door retaining fasteners.
Note: When the control box door is closed, the
calibration toggle switch is automatically activated
to exit out of calibration mode.
Part No. 1263382
Platform Components
2-5

Platform Overload System

Proper calibration of the platform overload system
is essential to safe machine operation. Continued
use of an improperly calibrated platform overload
system could result in the system failing to sense
an overloaded platform. The stability of the
machine is compromised and it could tip over.
How to Calibrate the Platform
Overload System
Note: Perform this procedure with the machine on
a firm, level surface.
1
Fully retract the boom and jib boom. Level the
platform.
2
Remove all equipment or tools from the
platform. Remove the welder if equipped.
3
Determine the maximum platform capacity.
Refer to the machine serial plate.
4
Push in the ground controls red Emergency
Stop button to the off position.
SX-135 XC
Service and Repair Manual
35