Wall Finishes / Surrounds / Mantels; Installation Preparation - Superior Fireplaces DRT4040DMN-B Installation And Operation Instruction Manual

Direct-vent
Table of Contents

Advertisement

Innovative Hearth Products
DRT4000 Series Direct-Vent Gas Fireplaces
Figure 6 - Combustible Side Clearances
At 6" (153 mm) mini-
At 6" minimum
mum side wall clear-
side wall clearance,
ance, a combustible
a combustible wall
wall can project to any
can project to any
length.
length.

Wall Finishes / Surrounds / Mantels

NOTE: Combustible wall finish materials and/or surround materials must not be allowed to encroach the area defined
by the fireplace front face (black sheet metal). Never allow combustible materials to be positioned in front of or
overlapping the fireplace face (Figure 40).
Non-combustible materials, such as surrounds and other fireplace trim, may be installed on the fireplace face, but they
must not cover any portion of the removable glass panel or control compartment.
Vertical installation clearances to combustible mantels vary according to the depth of the mantel (Figure 7). Mantels
constructed of non-combustible materials may be installed at any height above the fireplace opening. However, do
not allow anything to hang below the fireplace hood.
Minimum clearance requirements include any projections such as shelves, window sills, mantels, etc. above the
fireplace.
NOTE: To avoid heat-related finish damage, we recommend the use of high temperature paint (rated 175° F or higher) on
the underside of the mantel.

INSTALLATION PREPARATION

The fireplace is shipped with all gas controls and components installed and pre-wired. Before installing the fireplace,
follow these steps:
1. Remove the shipping carton, and retain the front of the carton (used to protect the fireplace during construction).
2. Remove the shipping pad, exposing the front glass door.
3. Remove the glass door (Page 56).
NOTE: Place the glass door on the shipping carton to protect its surface.
4. IMPORTANT: Remove the cardboard from beneath
each pressure relief plate (see Diagram A). To
remove, squeeze cardboard and pull down (be careful
not to damage the white gasket). Suggestion: On
some models, you may wish to remove the baffle (3
screws), for easier access. If removed, reinstall baffle
after cardboard is removed.
Top View of
Top View of
Fireplace
Fireplace
o
45
45°
Combustible materials allowed
in shaded area "Safe Zone".
6"
Combustible walls shown in
(153 mm)
dark gray
Combustible mantel legs may
project beyond either side of the
fireplace opening as long as they
are kept within the shaded area
illustrated here.
Figure 7 - Mantel Height
Mantel depth
22 (559)
20 (508)
18 (457)
16 (406)
14 (356)
12 (305)
8
12
(203)
(305)
10
6
(254)
(152)
in. (mm)
Remove Cardboard
(2 places) Before
Using Appliance
Diagram A
General Information
900697-01 01/2017
4
Hood
(102)
2
Fireplace
(51)
15