Wall Finishes / Surrounds / Mantels; Installation Preparation - Superior Fireplaces DRT2033TMN Installation And Operation Instractions

Direct-vent gas fireplaces
Table of Contents

Advertisement

Innovative Hearth Products
DRT2000 and DRC2000 Direct-Vent Fireplaces
Table 10 - Combustible Shelf Height—Rear Vent
Figure 6 - Combustible Side Clearances
At 6" minimum
side wall
clearance, a
At 6" minimum
side wall clearance,
combustible
a combustible wall
wall can project
can project to any
to any length.
length.
6" (152 mm)
6"

Wall Finishes / Surrounds / Mantels

NOTE: Combustible wall finish materials and/or surround materials must not be allowed to encroach the area defined
by the fireplace front face (black sheet metal). Never allow combustible materials to be positioned in front of or
overlapping the fireplace face (Figure 41).
Non-combustible materials, such as surrounds and other fireplace trim, may be installed on the fireplace face, but they
must not cover any portion of the removable glass panel or control compartment.
Vertical installation clearances to combustible mantels vary according to the depth of the mantel (Figure 7). Mantels
constructed of non-combustible materials may be installed at any height above the fireplace opening. However, do
not allow anything to hang below the fireplace hood.
Minimum clearance requirements include any projections such as shelves, window sills, mantels, etc. above the
fireplace.
NOTE: To avoid heat-related finish damage, we recommend the use of high temperature paint (rated 175° F or higher) on
the underside of the mantel.

INSTALLATION PREPARATION

The fireplace is shipped with all gas controls and components installed and pre-wired. Before installing the fireplace,
follow these steps:
1. Remove the shipping carton, and retain the front of the carton (used to protect the fireplace during construction).
2. Remove the shipping pad, exposing the front glass door.
3. Remove the glass door (Page 55).
NOTE: Place the glass door on the shipping carton to protect its surface.
Model
Secure Vent
33" Models
34" (864 mm)
35" Models
36-1/4" (921 mm)
40" Models
40-1/2" (1029 mm)
45" Models
45-1/2" (1156 mm)
Top View of
Top View of
Fireplace
Fireplace
Combustible materials
o
45
Combustible Materials
allowed in shaded area
o
3-1/2"
45
Allowed In Shaded Area
"Safe Zone".
(89 mm)
3-1/2"
"Safe Zone"
(89 mm)
Combustible walls
Combustible Walls
shown in dark gray
shown in dark gray
Combustible mantel
Combustible mantel legs may
legs may project
project beyond either side
beyond either side of
of the fireplace opening
the fireplace opening
as long as they are kept
as long as they are kept
within the shaded area
within the shaded area
illustrated here.
illustrated here.
(152 mm)
Rear Vent with two 90° Elbows
Secure Flex
(flex elbow)
®
®
34" (864 mm)
36-1/4" (921 mm)
40-1/2" (1029 mm)
45-1/2" (1156 mm)
Figure 7 - Mantel Height
18 (457)
16 (406)
14 (356)
12 (305)
10 (254)
8 (203)
12
(305)
10
(254)
in. (mm)
≥3" clearance from shelf to
top of fireplace and/or vent
pipe, whichever is higher
Shelf Height
(see table)
Mantel depth
4
8
Hood
(102)
(203)
6
2
Fireplace
(152)
(51)
General Information
900004-00, 03/2018
No
combustibles
or insulation
in the shaded
area between
the appliance
and the shelf
above it.
15