NOTE: The supplied 15 ft of 2-conductor wire has one end of each conductor connected to the gas valve circuit and
the other end of each conductor placed loose inside the bottom compartment.
In millivolt systems, do NOT connect a wall switch to a 120 V power supply.
Electronic Wiring
One of the following optional controls must be used:
See the Operation section on Page 49 for more details.
NOTE: Electronic models must be connected to the main power supply.
1. Route a 3-wire, 120 Vac, 60 Hz, 1 ph power supply to the fireplace junction box.
2. Remove the electrical inlet cover plate from the side of the unit by removing the plate's securing screws (Table 12).
3. If unit is not supplied with a strain relief, remove the cover plate knockout. Then, feed the power supply wire
4. Connect the black power supply wire to the lower outlet's red pigtail lead (Figures 32-33). Connect the white
5. Connect the ground supply wire to the pigtail lead attached to the outlet's green ground screw. Restrain the inlet
6. If a wall-mounted control switch is to be used, mount it in a convenient location on a wall near the fireplace.
7. If an optional control is to be used, wire it in the low voltage circuit (Figures 30-31).
8. After the wiring is complete, replace the cover plate.
Electronic models of these appliances are equipped with a three-prong (grounding)
plug utilized in connecting the electronic components to the junction box in the lower
compartment. This grounding plug provides protection against shock hazard and should be
plugged directly into a properly grounded three-prong receptacle. DO NOT cut or remove the
grounding prong from the plug.
38
Ecoflow Wireless Wall Switch (provided)
Unit-Mounted ON/OFF Control
Remote Control.
through the knockout opening and into the unit junction box.
power supply wire to the outlet's common terminal.
power lead per NEC or local codes.
NOTE: The supplied 15 ft of 2-conductor wire has one end of each conductor connected to the gas valve circuit
and the other end of each conductor placed loose inside the bottom compartment.
CAUTION
WARNING
Installation
900697-01 01/2017