Wall Finishes / Surrounds / Mantels

Clearances to combustible mantels vary according to mantel depth (Figure 6).
Mantels constructed of non-combustible material may be installed at any height above the appliance opening; however, do
NOT allow anything to hang below the top edge of the fireplace door.
Minimum clearance requirements include any projections such as shelves, window sills, mantels, etc. above the
fireplace.
NOTE: To avoid heat-related finish damage, we recommend the use of high temperature paint (rated 175°F or higher) on
the underside of the mantel.
NOTE: The factory-supplied non-combustible fiber board MUST be installed around the fireplace opening.
Figure 6 - Combustible Side Clearances

INSTALLATION PREPARATION

The fireplace is shipped with all gas controls and components installed and pre-wired. Before installing the fireplace,
follow these steps:
1. Remove and retain the shipping carton.
2. Confirm receipt of required items listed in Packaging on Page 8.
3. Retrieve the (3) pieces of non-combustible fiber board from behind the fireplace, and set aside in a safe location
4. If not already done, remove the barrier.
5. Remove the glass door (Page 59), and set aside in a secure location for later reinstallation.
6. Remove baffle and other items shipped inside firebox. Set aside in a secure location for later installation.
NOTICE: All DRL6500 model fireplaces
include a barrier to reduce the risk of burns
from hot viewing glass. This barrier in the
fireplace is a screen shown to the right.
16
At 14" minimum
side wall
clearance, a
At 8-1/4" side
combustible wall
wall clearance, a
can project to
combustible wall
any length.
can project 12"
o
45
14
14" (356
8-1/4"
8-1/4
(356)
(209)
mm)
(209 mm)
for later installation.
NOTE: Place the glass door on the shipping carton to protect its surface.
42" Barrier J7427
54" Barrier J7426
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Top View of
Fireplace
Combustible materials
allowed in shaded area
5" (127
5 (127)
"Safe Zone".
mm)
Combustible walls
shown in dark gray
12" (305
Combustible mantel
12 (305)
mm)
legs may project
beyond either side of
the fireplace opening
as long as they are kept
within the shaded area
17" (431
illustrated here.
17 (431)
mm)
Figure 7 - Mantel Height
Mantel depth
28 (711)
26 (660)
24 (610)
22 (559)
20 (508)
18 (457)
4
8
12
(102)
(203)
(305)
10
6
(254)
(152)
in. (mm)
General Information
900077-00, 01/2018
Fireplace
2
(51)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Drl6542tenDrl6554ten

Table of Contents