Superior Fireplaces DRT4040DMN-B Installation And Operation Instruction Manual page 20

Direct-vent
Table of Contents

Advertisement

Innovative Hearth Products
DRT4000 Series Direct-Vent Gas Fireplaces
Rough in the Electrical Supply, if Needed
6.
As necessary, rough in the fireplace electrical supply per NEC and local codes.
Install the [Optional] Blower Kit before Installation in the Framing
7.
1. Remove the left side blower cover panel screw, and blower cover panel (see Table 12, Page 17). Retain the
2. Slide the blower through the opening and position it with the bracket oriented to the front of the firebox and the
3. Reinstall the blower cover panel and secure with the removed screw.
4. Access the blower supply wiring through the front of the fireplace and plug it into the junction box in the right,
5. Install the blower control switch according to its included instructions.
20
panel and screw for later reinstallation.
blower discharge to the rear of the firebox. Bend the two tabs in the firebox floor to secure the blower to the
floor.
rear of the fireplace (Figure 32).
Installation
900697-01 01/2017

Advertisement

Table of Contents
loading

Table of Contents