Checking The Drive Module; Checking The Controller; Emergency Repair Procedures; Figure 6-25 Jumper Assembly - Carrier 69NT40-511-310 Operation & Service Manual

Hide thumbs Also See for 69NT40-511-310:
Table of Contents

Advertisement

the suction gauge. Within one minute the suction
pressure will go into a vacuum. This is an indication
that the valve is moving.
4. If no change in suction pressure is detected, check
for resistance (refer to step 6.18.2), and check con-
nections for proper continuity and retest. If the valve
is functioning and all connections and motor resist-
ance are good, check the drive module. (Refer to
step 6.18.3)
5. If the valve is determined as faulty after completing
the above steps, perform a low side pump down. Re-
move valve powerhead assembly, and replace with a
NEW valve powerhead assembly, torque nut to 35 ft-
lb, evacuate low side, and open all service valves.
DO NOT disassemble piston from NEW suc-
tion modulating valve powerhead assem-
bly. Doing so may result in damage to pis-
ton.

6.18.3 Checking The Drive Module

a. Turn unit OFF.
b. Disconnect the four pin connector to the SMV.
c. With voltmeter set to read 24 volts AC, attach the pos-
itive lead to the drive module outlet pin "A" (wire 1A) of
the four pin connector and the negative lead to the "B"
pin (wire 1B).
d. Turn ON unit, and watch the volt meter. After a short
delay, the reading should rise to approximately 12
volts.
e. Repeat for pins "C" and "D" (wires 2 A and 2 B).
f. If only one set of pins reads a voltage, check connec-
tions and retest.
g. If the retest reads out the same, the drive module or
controller is faulty.
h. If no voltage is present in any step, the output from the
controller to the drive module may be faulty, and will
require checking the connections and wires from the
controller to the drive module. Refer to step 6.18.4
i. To replace the drive module, disconnect all connec-
tors, unscrew from mounting, and replace with a
NEW drive module in reverse order.

6.18.4 Checking The Controller

a.
Turn the unit OFF.
b. Disconnect the six pin connector to the stepper drive
from the controller.
c. With the voltmeter set to read 50 volts DC, attach the
positive lead to outlet pin "A" of the six pin connector,
and the negative lead to pin "B" or TP-9 of the con-
troller.
d. Turn ON the unit for 40 seconds, and watch the volt-
meter. There should be approximately 24 to 32 VDC
shown on pin "A".
e. There should be zero volts on pin "B".
f. After a short delay, the reading should rise to approx-
imately 24 to 32 VDC on pin "E".
T-296
Downloaded from
ManualsNet.com
CAUTION
search engine
g. Pins "C" and "D" will have zero to 5 volts transistor
logic (TTL) signals present, however, this can only
be checked with the connector assembled as this is
an open collector type circuit.
By checking the outputs on "A," "B," and "E" it can be
verified that the controller is supplying power to the drive
module. To be thorough, and if it is desired, the signals
on pins "C" and "D" can be checked as follows:
1. Install a jumper assembly (Carrier part number
07--00408--00) to connect the drive module and con-
troller connectors as shown in Figure Figure 6-25.
2. Connect the positive lead of the voltmeter to test
connector socket "C" and negative lead to socket
"B," and run as before by resetting unit.
3. Repeat for sockets "D" and "B."
Controller
Connector (EC)
A
B
C
D
E
Test
Connector

Figure 6-25 Jumper Assembly

There should be approximately five volts DC on sockets
"C" and "D" (S1 and S2) when measured as above. If not
the connections or controller is faulty.
If any of these pins are not consistent, the connections
or controller is suspect. Check and replace as required.

6.18.5 Emergency Repair Procedures:

In the event that the SMV system has a failure and
replacement components are not readily available the
system can be by--passed by removing the valve piston.
to remove the piston, do the following:
a. Perform a low side pump down. Refer to paragraph
6.4.
b. Remove SMV powerhead by loosening the 2-1/8
inch diameter nut (see Figure 6-24) to relieve any
pressure and then , sliding the powerhead out.
c. Remove the piston by loosening the Allen screw and
removing the piston and screw.
d. Install the powerhead assembly (without the piston),
torque to 35 to 40 foot-lbs.
e. Open all valves.
f. Start the unit.
g. Adjust the suction service valve so that the approxi-
mate temperature OR current limit is maintained.
For perishable loads, it is recommended that the ad-
justment be made so that the available capacity is
slightly larger than the load, the unit will cycle OFF
and ON.
h. Once repair parts become available, repair as re-
quired.
6-18
Drive Module
Connector (SD)
Jumper
A
B
C
D
E

Advertisement