Sensor Configuration (Dcf02); Table 3-2 Datacorder Configuration Variables; Table 3-3 Datacorder Standard Configurations - Carrier 69NT40-511-310 Operation & Service Manual

Hide thumbs Also See for 69NT40-511-310:
Table of Contents

Advertisement

CONFIGURATION NO.
dCF01
dCF02
dCF03
dCF04
dCF05
dCF06
dCF07
dCF08
dCF09
dCF10
b. Configuration Software
The configuration software controls the recording and
alarm functions of the DataCORDER. Reprogramming
to the factory installed configuration is achieved via the
same configuration card as the unit control module
software. Changes to the software may be made made
using the Data View integration device. A listing of the
configuration variables is provided in Table 3-2.
Descriptions of DataCORDER operation for each
variable setting are provided in the following
paragraphs.

3.6.3 Sensor Configuration (dCF02)

Two modes of operation may be configured, the
Standard Mode and the Generic Mode.
a. Standard Mode
In the standard mode, the user may configure the
DataCORDER to record data using one of seven
standard
configurations.
configuration variables, with their descriptions, are
listed in Table 3-3.
The six thermistor inputs (supply, return, USDA #1, #2,
#3 and cargo probe) and the humidity sensor input will
be generated by the DataCORDER. An example of a
report using a standard configuration is shown in
Figure 3- 5.
The DataCORDER software uses the supply
and return recorder sensors. The temperature
control software uses the supply and return
temperature sensors.
b. Generic Mode
The generic recording mode allows user selection of the
network data points to be recorded. The user may select
up to a total of eight data points for recording. A list of the
data points available for recording follows. Changing the
configuration to generic and selecting which data points
to record may be done using the Carrier Transicold Data
Retrieval Program.
1. Control mode
2. Control temperature
3. Frequency
4. Humidity
T-296
Downloaded from
ManualsNet.com

Table 3-2 DataCORDER Configuration Variables

(Future Use)
Sensor Configuration
Logging Interval (Minutes)
Thermistor Format
Thermistor Sampling Type
Controlled Atmosphere/Humidity Sampling Type
Alarm Configuration USDA Sensor 1
Alarm Configuration USDA Sensor 2
Alarm Configuration USDA Sensor 3
Alarm Configuration Cargo Sensor
The
seven
NOTE
search engine
TITLE
5. Phase A current
6. Phase B current
7. Phase C current
8. Main voltage
9. Suction modulation valve percentage
10. Discrete outputs (Bit mapped -- require special
handling if used)
11. Discrete inputs (Bit mapped -- require special
handling if used)
12. Ambient sensor
13. Compressor suction sensor
14. Compressor discharge sensor
15. Return temperature sensor
16. Supply temperature sensor
17 Defrost temperature sensor
18. Discharge pressure transducer
19. Suction pressure transducer
20. Condenser pressure transducer

Table 3-3 DataCORDER Standard Configurations

standard
Standard
Config.
2 sensors
(dCF02=2)
5 sensors
(dCF02=5)
6 sensors
(dCF02=6)
9 sensors
(dCF02=9)
6 sensors
(dCF02=54)
7 sensors
(dCF02=64)
10 sensors
(dCF02=94)
3-8
DEFAULT
OPTION
----
2
2,5,6,9,54,64,94
60
15,30,60,120
Short
Low, Normal
A
A,b,C
A
A
Auto, On, Off
A
Auto, On, Off
A
Auto, On, Off
A
Auto, On, Off
Description
2 thermistor inputs(supply & return)
2 thermistor inputs(supply & return)
3 USDA thermistor inputs
2 thermistor inputs(supply & return)
3 USDA thermistor inputs
1 humidity input
Not Applicable
2 thermistor inputs(supply & return)
3 USDA thermistor inputs
1 cargo probe (thermistor input)
2 thermistor inputs(supply & return)
3 USDA thermistor inputs
1 humidity input
1 cargo probe (thermistor input)
2 thermistor inputs(supply & return)
3 USDA thermistor inputs
1 humidity input
1 cargo probe (thermistor input)
3 C.A. inputs (NOT APPLICABLE)
----
A,b