2.2

Startup

Outline

This chapter describes the setting procedure for CC-Link IE Field Network Basic. Refer to the following manual for startup of
the servo amplifier.
MR-J5-G/MR-J5W-G User's Manual (Introduction)
MR-J5D-G User's Manual (Introduction)
• To ensure the safety of the system against unauthorized network access, take security measures such as
using a firewall.
• When the value of [Pr. PN02 Communication error - Detection time] is small, [AL. 086 Network
communication error] may occur when the power of the servo amplifier is cycled or an instantaneous power
failure occurs during CC-Link IE Field Network Basic communication.

Network setting

• [Pr. PN13.0-3 Network protocol setting] is set to "0000h" (CC-Link IE TSN) at the factory setting. When
using with CC-Link IE Field Network Basic, set [Pr. PN13.0-3] to "0004h".
• The communication speed is set to 1 Gbps at the factory setting. Since CC-Link IE Field Network Basic
communicates at 100 Mbps, communication will not be established if a device whose communication speed
is 1 Gbps is also connected. In such case, rewrite [Pr. PN13.0-3] from the engineering tool with a USB
connection, or connect a device set with the same communication speed and rewrite [Pr. PN13.0-3] via the
network.
Set the parameters of GX Works2 or GX Works3 as required for the servo amplifier network settings, and then configure the
network settings of the master station and servo amplifier. Set the network settings of the master station and servo amplifier of
CC-Link IE Field Network Basic according to the following procedure.
If an alarm has occurred, refer to the following manual.
MR-J5 User's Manual (Troubleshooting)
1.
Profile (CSP+ file) settings
Set the latest profile (CSP+ file).
Page 85 Profile (CSP+ file) settings
2.
Master station setting
Refer to the GX Works2 or GX Works3 manual.
3.
IP address setting
Set the IP address with the rotary switches and a parameter.
MR-J5-G/MR-J5W-G User's Manual (Introduction)
MR-J5D-G User's Manual (Introduction)
Refer to the following when setting with parameters.
Page 87 IP address setting function
4.
Parameter setting
Page 85 Parameter setting
5.
Network connection procedure
Page 86 Network connection procedure
6.
Cyclic communication establishment procedure
Page 86 Cyclic communication establishment procedure
2 CC-Link IE Field Network Basic
84
2.2 Startup

Advertisement