The monitor processor contains the logs that are found in these processors:
2 – Pitch Servo
4 – Roll Servo
6 - Yaw
8 – Pitch Trim Servo
There are two main groupings of faults that can occur in the monitor processor.
The first grouping of faults can occur during the GSA unit pre-flight test (PFT). If there is
a fault during PFT the unit will not be able to transition to normal mode and the only way
to clear this state would be to cycle unit power. The second grouping of faults can occur
during normal mode. These faults generally cause a disconnect of power to the GSA and
report that a fault has occurred to the GIA.
Monitor PFT Step
INTERNAL COMM FAIL
UNSW POWER INV
MON SOL PWR ON FAIL
CTL SOL PWR ON FAIL
SOL PWR FAIL
CERT DATA UNINSTALLED
STRAP MODE MISMATCH
____________________________________________________________________________
LMM for the Kodiak 100
190-02102-00 Rev.4
Table 4-22. PFT Faults
This can sometimes be the result of a failure on the
other internal servo board. Check faults on the
other processor.
Check unit power.
Check unit power and AP Disconnect power.
GSA only. Check unit power and AP Disconnect
power.
Check unit power and AP Disconnect power.
Upload the certification gain file to the Monitor Board.
Check the connector strap inputs to the unit.
Notes
Page 4-101