Symptom: The Heat Exchanger Unit Fan Does Not Spin; Symptom: The Display Shows "88; Symptom: The Compressor In The Compressor Unit Does Not Stop After A Short Heating Operation; Symptom: The Inside Of An Compressor Unit Is Warm Even When The Unit Has Stopped - Daikin RDXYQ5T8V1B Installer And User Manual

Heat pump for indoor installation
Table of Contents

Advertisement

10
|
Troubleshooting

10.2.14 Symptom: The heat exchanger unit fan does not spin

10.2.15 Symptom: The display shows "88"

10.2.16 Symptom: The compressor in the compressor unit does not stop after a short heating
operation

10.2.17 Symptom: The inside of an compressor unit is warm even when the unit has stopped

10.2.18 Symptom: Hot air can be felt when the indoor unit is stopped

Installer and user reference guide
44
During operation. The speed of the fan is controlled in order to optimise product
operation.
This is the case immediately after the main power supply switch is turned on and
means that the user interface is in normal condition. This continues for 1 minute.
This is to prevent refrigerant from remaining in the compressor. The unit will stop
after 5 to 10 minutes.
This is because the crankcase heater is warming the compressor so that the
compressor can start smoothly.
Several different indoor units are being run on the same system. When another
unit is running, some refrigerant will still flow through the unit.