If you replace:
Convergence
/ Adjustment
LCD Green
Unit
LCD Blue Unit
LCD Red Unit
3. When any adjustments 4.4.1 through 4.4.4, 4.4.12 and 4.4.13 are
necessary, please refer to "Preparation for Adjustments 4.4.1
through 4.4.4, 4.4.12 and 4.4.13".
4. When an adjustment 4.4.5 is necessary, please refer to
"Preparation for Adjustment 4.4.5".
5. When any adjustments 4.4.14 through 4.4.17 are necessary,
please refer to "Preparation for Adjustments 4.4.14 through
4.4.17".
6. Polarizer unit: Incidence side
Polarizer: Outgoing side
4.1.1. The Factory Adjust Mode
All Electrical Adjustments are performed on the Factory Adjust Mode which is used remote
control unit instead of variable resistor to control the adjustment value.
1. Connect a jumper wire between TP6014 and TP6015 on Main
C.B.A. for over 5 seconds to enter the Factory Adjust Mode.
2. Press the remote control
button to set the item to be adjusted.
necessary Convergence
Adjustment
R-G /
B-G /
Convergence
/ Adjustment
or
to select and press
Fig. 4-1-1
or