Adjusting For Orientation Error; Installing The Display Unit; Desktop, Overhead Mounting - Furuno SC-60 Operator's Manual

Satellite compass
Table of Contents

Advertisement

2. INSTALLATION
2.3.4

Adjusting for orientation error

It may be impossible to perfectly align the processor unit on the fore-and-aft or
port-and-starboard line. Open the top cover, loosen the two fixing screws on the
angular rate sensor and turn. For example, if the orientation error is 2.5 to port,
rotate the sensor 2.5 starboard The range of adjustment is -45 to +45 Close
the top cover after completing the adjustment.
Reference
Direction
2.4

Installing the Display Unit

2.4.1

Desktop, overhead mounting

1. Fasten the hanger to the mounting location with four tapping screws
(supplied). See the outline drawing for mounting dimensions.
2. Screw the knobs into the display unit.
3. Set display unit to the hanger and tighten the knobs.
4. Run the ground wire between the ground terminal on the display unit and the
ship's superstructure.
2-14
Scale
Angular rate sensor, top view
Desktop
Display unit mounting methods
Bow-stern, Port-starboard
direction
Processor Unit
Hole on processor unit
Graduation, every
2.5
°
Bulkhead Mounting
Plate
Fixing Screw
Overhead

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents