4. Loosen four screws on the angular rate sensor mounting base, and then
fasten the bulkhead mounting plate to the angular rate sensor mounting
base.
Angular Rate Sensor
Angular
Rate
Sensor
Mounting
Base
5. Close the top cover of the processor unit.
6. Partially screw in two tapping screws for the top fixing holes of the processor
unit in the mounting location. Hang the processor unit on the tapping screws,
using the top fixing holes. Screw in two tapping screws for the bottom fixing
holes, and then tighten the top fixing holes.
Bulkhead Mounting Plate
20P8171
Processor unit, top view
2. INSTALLATION
Top Fixing
Hole (x2)